Description:
The RD6 ANT RD6-W series 3 phase sequence voltage monitoring relay are Ideal for Monitoring 3-phase Power Supplies for Industrial Facilities and Equipment, and for incorrect phase sequence, phase failure and phase imbalance on systems up to 500V.Phase failure.It is used to ensure the sequence is correct when connecting 3 phase loads. With an incorrect phase sequence the relay will start to de-energise, preventing the starting of incorrectly connected machinery. The relay will also trip if there is a phase loss and can therefore be used as a phase failure relay.Phase Sequence Relay controls the order of 3 phases feeding motors. If R,S and T phases are in correct order, ON LED on the front panel is turned on. If the phase order is wrong, ON LED is turned off and the output relay is switched to OFF. Phase sequence relay is used to protect 3 phase motors in systems of air compressors, elevator and etc. FR-02 is recommended to use in applications where unexpected false rotating direction of motors can cause injury to person and damage the property.
Phase Imbalance
Incorrect Phase Sequence
Features:
- 3-phase phase sequence phase loss imbalance detection
- Secures against phase breaking
- Made in accordance with the CE and EMC regulations
- LED indicators for power supply,
- relay and reaction timer
- Individual unique counting function
- Wide range input voltage AC200-500V
- Only operational with correct power source voltage and phase sequence
- Suitable for main power source and motor starter circuit to prevent damage from insufficient phase reversal
- Out-of-phase detection while the motor operating
- Selectable Over/Under voltage trip level
- Selectable Time Delay
- Application
- Protect motors and other equipment from unstable voltages in the power supply system.
Protect motors and other equipment by detecting over voltages, under voltages, phase sequence
phase loss for three-phase power supplies
Model | RD6-W | ||
Rated Voltage | AC200-500V | Actuation time | 0.1-20s |
Rated frequency | 50/60Hz | Counting voltage | AC/DC24V,AC80-250VV,AC380V |
Rated power | ≤20W | Counting capacity | 999999times |
Voltage display | 150-500V | Time capacity | 9999hours and 59minutes |
Measurement Accuracy | +/-1% | Measuring Precision | 0.1% |
Over voltage setting | 380~500V | Contact material | Agsno |
Under voltage setting | 200~365V | Contact lift | 2X10"7 |
Material | fire resistance ABS | Contact Type | 2N.O/1N.C |
Protection class | IP40 | Contact capacity | 5A/280VAC,8A/30VDC |
Time capacity | 9999hours and 59minutes | Operation Temperature | -45~85ºC |
Protection class | IP40 | Material | fire resistance ABS |