Measuring current in a system is a fundamental, yet powerful tool in monitoring the system’s state. With advanced technology, electronic or electrical systems are tremendously shrinking in physical size, reducing power dissipation and cost with not much tradeoff in terms of performance. Every electronic device is monitoring its own health and state, where these diagnostics provide vital information needed to manage the system and even dictate its future design upgrades.
There is a growing need to measure a wide range of current in a system from miniscule current levels to several Amperes of current. For example, ascertaining the high dynamic range of current flowing or consumption in a system can be seen in the following cases:
Figure 1. Current-Sense Amplifier (CSA) + sense resistor.
Figure 1 shows a CSA with a sense resistor. In presence of higher voltage level (common-mode levels) applications up to 80V, a simple current sense amplifier (CSA) on the outside (but a complex integrated circuit design with architecture catered towards precision and accuracy) and a sense resistor is the solution to most of the problems when measuring current. Current sense amplifiers currently come with best in class accuracy and precision to tackle the demand of realizing micro-ampere current levels and still maintain better signal-to-noise ratio (SNR) performance to provide the resolution of measurement the system design is looking for.
However, it is not an easy task when come to selecting an optimized CSA for designers. There are tradeoffs that should be taken into considerations (Figure 2):
Figure 2. Design constraints to consider when using CSA and RSENSE.
Since the differential voltage range is set by the choice of the current sense amplifier, increasing the RSENSE value improves the accuracy of the measurements for lower values of the current, but the power dissipation is higher at higher current and that may not be acceptable. Also, the range of the sensed current is reduced (IMIN : IMAX).
Reducing the RSENSE value is more beneficial as it reduces power dissipation of the resistor, increases the sensed current range. Reducing the RSENSE value reduces the SNR (which may be improved with averaging to average the noise at the input). It should be noted that during this scenario the offset of the device affects the accuracy of the measurement. Oftentimes, calibration at room temperature is done to improve system accuracy, cancelling out the offset voltage with addition of test cost for certain systems.
Also, the input differential voltage range (VSENSE) is dependent on the supply voltage or the internal/external reference voltage and the gain:
In any application realizing high current ranges, the goal is to maximize the dynamic range for a targeted accuracy budget, which is typically estimated by the equation below:
VSENSE-RANGE is typically 100mV for most CSAs with an input offset voltage of approximately 10μV. Note that If VSENSE_MIN is chosen to be a 10xVOS factor, this provides 3 decades at best for a ±10% errors in an un-calibrated system. Similarly, if a 100xVOS is selected, a ±1% error range can be achieved but then the dynamic range is shrunk to 2 decades. As a result, there is a tradeoff between dynamic range and accuracy: tightening the accuracy budget reduces the dynamic range dictated by the VSENSE_MIN and vice versa.
A point to note is that in a CSA + RSENSE system, RSENSE (tolerance and temperature coefficient) is usually the bottleneck of total accuracy of the system. This is still the industry’s efficient practice to monitor/measure currents in a system thanks to its simplicity, reliability and reasonable costs compared to other alternatives such as Fuel gauges, CSA’s with integrated chip resistor, discrete implementation of difference amplifiers using Op-Amps. Higher grade tolerance and temperature coefficient sense resistors can be found but only at steeper prices. The total error budget of the application over temperature needs to be equivalent to the error emerging from the RSENSE.
When it comes to applications that require higher dynamic range of currents to be measured from a couple of hundreds of microamperes to several amperes, an integrated current sensing device (U1) shown in Figure 3 below is highly useful, effective solution. The solution meets the bill in the following criteria:
Figure 3: 2.5V to 5.5V Current Sensing System with Integrated Current Sensing Element
Instead of an external sense resistor, an integrated sensing device is present across VDD input and load (LD) output, capable of measuring the system load current (ILOAD) from 100uA to 3.3A. An internal gain block with the gain of 1/500 provides the output current at ISH, which is . A 160Ω resistor connecting from ISH current output to GND, converts to VISH voltage output from 0V to 1V.
The drop across VDD and LD on the sensing element device is approximately 60mV at 3A of load current (Plot 1), equivalent to a mere 180mW power dissipation while at lower current values, the total error observed to sense 100μA range is in the region of 10% (Plot 2). Together with less power dissipation at higher current loads and still maintaining improved error budget at lower current levels, this scheme prevails the traditional sense circuit of Figure 1. Hence, applications requiring wider current sensing ranges up to 3A of sensing can benefit from this scheme.
Resistor-less Sensing Solution with Extended Line/Input Voltage:
Figure 4 is an input voltage range extension of Figure 3, where the supply voltage for U1 can now accept the line voltage higher, up to 6V to 36V. The Zener diode (D1) maintains the voltage across VDD and gate of the PFET (M1) to 5.6 V. The bulk of the high voltage line is absorbed by M1 with the M1’s source clamped to approximately 4V-4.5V away from the VDD input voltage, thus maintaining the U1 operating voltage (VDD-VSS) within its normal operating range (Plot 3). This M1’s source voltage is then biasing the gate voltage for M2 PFET. M2 PFET source is at VSS (U1) + VTH (M2) making sure U1 ISH output is within acceptable voltage levels. The ISH current output and R1 generates 0 to 1V output with respect to GND.
Figure 4. A 6V to 36V Current Sensing System with Integrated Current Sensing Element
Below are experimental results from the circuit of Figure 4.
Plot 1: Voltage Drop across the Internal Sense Element vs. Load Current
Plot 2: Gain Error at ISH output vs. Load current at different temperatures
Plot 3: Function of MAX40016 Supply Voltage (VDD-VSS) vs. VLINE
Plot 4. Load transient response with ILOAD step change from 0 to 3A.
Plot 5. Power-up transient response with 3A ILOAD.
As has been shown, a resistor-less sensing approach makes it possible to design a 4-decade current sensing architecture with extended operating range up to 36V.
[Note: All figures and plots are courtesy of Maxim Integrated.]
For more Embedded, subscribe to Embedded’s weekly email newsletter.
You must Sign in or Register to post a comment.
This site uses Akismet to reduce spam. Learn how your comment data is processed.
Your account has been deactivated.
Sorry, we could not verify that email address.
Your account has been reactivated.
You must verify your email address before signing in. Check your email for your verification email, or enter your email address in the form below to resend the email.
Please confirm the information below before signing in. Already have an account? Sign In.
We have sent a confirmation email to {* emailAddressData *}. Please check your email and click on the link to verify your email address.
We've sent an email with instructions to create a new password. Your existing password has not been changed.
Sorry, we could not verify that email address. Enter your email below, and we'll send you another email.
Check your email for a link to verify your email address.
Thank you for verifiying your email address. Sign in
Your password has been successfully updated.
We didn't recognize that password reset code. Enter your email below, and we'll send you another email.
We've sent you an email with instructions to create a new password. Your existing password has not been changed.